1994
The International Symposium on R22 & R502 Alternative Refrigerants
Performance Evaluations and Commercialization Issue for Air Conditioning and Refrigeration Equipments
December 8 (Thursday) - 9 (Friday), 1994
| Masahiro Miyazaki, Director ー Ozone Layer Protection Office, Ministry of International Trade and Industry, Japan |
| Keisuke Tachibana, President, Japan Refrigeration and Air Conditioning Industry Association, Japan |
| Steve Szymursky, Manager, R&T Dept., ARI, U.S.A. |
| Akira Fujitaka, Matsushita Electric Industrial Co., Ltd., Japan |
| Experimental Evaluation of Room Air Conditioner using R32/125/134a Blends |
| Koichi Furuhama, Toshiba Corporation, Japan |
| Performance Evaluation of Residential Air Conditioner with R32/125 Mixture |
| Ryuzaburo Yajima, Daikin Industries, Ltd., Japan |
| The Performance Evaluation of Various HFC Alternative Refrigerant Mixtures |
| Hideaki Kasahara, Mitsubishi Heavy Industries, Ltd., Japan |
| Packaged Air Conditioner with a Refrigerant Mixture of R32/125/134a |
| Shigeya Ishigaki, Sanyo Electric Co., Ltd., Japan |
| Performance Improvement of Room Air Conditioner with Referent Mixture R32/125/134a |
| David Treadwell, Lennox Industries Inc., U.S.A. |
| Performance, Cost and Safety Refrigerants of Employing R290, Propane) in Unitary A/C Equipment |
| Masahiro Nakayama, Mitsubishi Electric Corporation, Japan |
| R32/125/134a Cycle Composition Change and its Effect on the System Performance |
| Kensaku Oguni, Hitachi, Ltd., Japan |
| Characteristics of Refrigeration System Utilizing Refrigerant Mixture R32/125/134a |
| Kazuhiko Marumoto, Matsushita Refrigeration Company, Japan |
| Composition Shift of R32/125/134a In Multiple Air Conditioners |
| Steven R. Szymursky, Air-Conditioning and Refrigeration Institute, U.S.A. |
| Materials Compatibility and Lubricants Research (MCLR) Program |
| Akira Matsui, Kobe Steel, Ltd., Japan |
| As to Drop-in Test of R32/125/134a in Screw Chiller |
| Katsumi Hachisuka, Mitsubishi Heavy Industries, Ltd., Japan |
| Performance of Low Temperature Refrigeration with R125/143a/134a |
| Hiroshi Namiki, Mayekawa Mfg. Co., Ltd., Japan |
| The Trends in Ammonia for Industrial Refrigeration Plants |
| Toshiaki Yamaguchi, Mitsubishi Electric Corporation, Japan |
| Characteristics of Scroll Condensing Units for R125/143a/134a |
| Syunji Komatsu, Sanden Corporation, Japan |
| Performance of Chest Freezer with R125/143a/134a |
| Sung Lim Kwon Thermo King Corporation, U.S.A |
| Evaluations of R-22 and R-502 Alternatives for Transport Refrigeration |
| Makoto Hayano, Toshiba Corporation, Japan |
| Calorimeter Test of Rotary Compressors with HFC-blend Refrigerants |
| Tadashi Iizuka, Hitachi, Ltd., Japan |
| Reliability of Compressors for HFC-based Refrigerants |
| Yoshinobu Obokata, Sanyo Electric Co., Ltd., Japan |
| Reliability Study in a Rotary Compressor for HFC Refrigerants Mixture |
| Hideo Hirano, Matsushita Electric Industrial Co., Ltd., Japan |
| Evaluation of Lubricants for HFC Refrigerants |
| Sonny Sundaresan, Copeland Corporation, U.S.A. |
| Compressor Tribology and Other System Requirements for POE Lubricants with HFC Refrigerants |
| Masayoshi Muraki, Mitsubishi Oil Co., Ltd., Japan |
| Polyol Ester Lubricants for Alternative Refrigerants |
| Kenichi Ueshima, ICI Japan Limited, Japan |
| Properties of Polyol Ester Oil and Examples for Refrigerants |
| Minoru Takagi, Idemitsu Kosan Co., Ltd., Japan |
| New Non-Ester Type Lubricants for Alternative Refrigerants |
| Naoya Sakamoto, Mitsui Petrochemical Industries. Ltd., Japan |
| New Lube Oil for Unitary Air Conditioner |
| Motoshi Sunami, Nippon Oil Company, Ltd., Japan |
| New Immiscible Lubricant for HFCs |
| Shigeru Adachi, Union Showa K.K., Japan |
| Development of Molecular Sieve Desiccants for Alternative Refrigerants |
| Keiichi Maruo, Daikin Industries Ltd., Japan |
| The Development of CFC and HCFC Alternatives for Refrigerant |
| R.E.Low, ICI Chemicals & Polymers Ltd., U.K. |
| Performance Testing of R-22 and R-502 Alternatives Based on R-32/R-125/R134a |
| Akimichi Yokozeki, E.I. DuPont de Nemoures and Co. Fluorochemicals, U.S.A. |
| Characteristics of Alternative Refrigerant Mixtures |
| Haruo Ohnishi, Daikin Industries Ltd., Japan |
| The Current Status and Remain Issues for Evaluation of Refrigerant Safety |
| Donald Grob, Underwriters Laboratories Inc., U.S.A. |
| Flammable Refrigerants and UL Products Safety Standard |
| William Geoetzler, Arthur D. Little, Inc., U.S.A. |
| Risk Assessments for Flammable Refrigerants |
| Thomas Watson, MaQuay International, U.S.A. |
| ASHRAE Standards and Alternative Refrigerants |